REQUEST A QUOTE  -  STREAMLINED BACKSHOP INSTALLATIONS AND REPAIRS  -  MORE INFO 
ESU - Electronic Solutions Ulm

ESU 59626 LokPilot 5 Standard NMRA DCC Decoder - NEM651 6-pin Wired Plug

(No reviews yet) Write a Review
UPC:
404464559626
MPN:
59626
Condition:
New

Save More With Volume Discounts…

Buy 5 - 9 $41.04 each
Buy 10 or above $39.79 each
  • ESU 59626 LokPilot 5 Standard NMRA DCC Decoder - NEM651 6-pin Wired Plug
  • ESU 59626 LokPilot 5 Standard NMRA DCC Decoder - NEM651 6-pin Wired Plug
MSRP: CAD $52.35
Price: CAD $41.88
— You save CAD $10.47

Description

ESU 59626 LokPilot 5 Standard NMRA DCC Decoder - NEM651 6-pin Wired Plug


The LokPilot 5 DCC is the "twin brother" of the LokPilot 5. The two share almost all characteristics, however, the LokPilot 5 DCC is a pure DCC decoder and cannot be used on analog AC systems. This lack of flexibility comes with a cheaper price.

LokPilot 5 decoders are offered with all common interfaces.

Modes

The LokPilot 5 DCC is a "pure-bred" DCC decoder. 14 to 128 speed steps are as natural as 2- and 4-digit addresses. Up to 32 functions can be triggered. Thanks to RailComPlus® the decoders register automatically with a suitable DCC system like the ESU CabControl.

The decoder accepts all DCC programming modes and thanks to RailCom® the CV values ​​can be read on the main track with RailCom equipped DCC systems. For command stations that only program the CVs from 1-255 auxiliary CV registers exist.

The LokPilot 5 DCC decoder recognizes the Märklin® braking sections as well as the ZIMO® HLU / ZACKCommands or the Lenz® ABC system. Also braking with DCC brake modules or with DC voltageis possible. It also stops with a Selectrix® brake diode. An ABC automatic shuttle trainenables automatic commuting between two train stations.

The LokPilot 5 DCC decoder can be used on analog DC trains. The top speedcan be set separately.

The decoder switches between the operating modes fully automatically "on-the-fly".

Features

We know that you want your locomotives to be as realistic as possible. Therefore we have the LokPilot 5DCC packed with function outputs. Depending on the interface version, each LokPilot offers 5 DCCDecoder at least 10 amplified function outputs with 250mA output current each. In the executionswith PluX22 or 21MTC interface there are 4 outputs to control servos orLogic level outputs added. All-important lighting functions are available. The brightness of each outputcan be set separately. The decoder masters automatic pushing and pullingwhen uncoupling for ROCO®, Krois® and Telex® couplings.

Motor control

The engine control of the LokPilot 5 DCC has been fundamentally improved again. A variably adjustablePWM clock frequency from 10kHz to 50kHz ensures super quiet operation, especially with bell-armature motors.Operation - The typical “hum” is a thing of the past. The load control now has up to10 CVs which can be adjusted for difficult cases. The unique "Autotune" function enablesthe automatic calibration of the decoder to the motor. The LokPilot 5 DCC decoder delivers up to 1.5A of motor current. Enough juice even for older motors.

Operational safety

On request, a PowerPack can be fitted to the LokPilot 5 DCC to bridge dirty rail sections.

Protection

Of course, all function outputs and the motor output are protected against overload.

We want you to enjoy your decoder for as long as possible.

Decoder Specifications:

  • Size: 21.4 mm x 15.5 mm x 4.5 mm  (0.84 in x 0.61 in x 0.18 in)
  • Connection: NEM651 6-pin Wired Plug
  • Motor Rating: 1.5A Continuous
  • BEMF: Motor control with 50 kHz clock frequency
  • Functions:  10 amplified outputs for special functions, 4 Logic-level outputs, 2 Servo Outputs (total: Up to 16 outputs)
  • Protocol: DCC with RailComPlus®
  • Additional Features:
    • Updatable with ESU-LokProgrammer
    • Two-stage heavy load simulation
    • 3 new, individually adjustable brake controllers
    • Connection interface for RC servos and SUSI modules
    • Optional optional PowerPack storage capacitor connections
 Interface
  • NEM652 8-pin Wired Plug
  • NEM658 PluX22 Integral Connector
  • NEM651 6-pin Wired Plug
  • NEM660 21MTC Integral Connector
  • NEM660 21MTC Integral Connector MKL
 
View AllClose

Additional Resources

MANUFACTURERS WEBSITE:
SOUND CONFIGURATION & SOUND FILE RESOURCES:
FIRMWARE & SOFTWARE RESOURCES:
PRODUCT MANUALS & TECHNICAL DOCUMENT RESOURCES:
MANUFACTURERS WARRANTY & REPAIRS:
ADDITIONAL INFORMATION - DCC TIPS:
ADDITIONAL INFORMATION (1):
ADDITIONAL INFORMATION (2):
View AllClose

Additional Information

PRODUCT CLASS :
Standard (HO-S-O*)
DECODER TYPE:
Motor + Function
DECODER INTERFACE (PRIMARY):
NEM651 - NMRA 6-pin
DECODER INTERFACE (SECONDARY):
NA
SIZE-INCH (L x W x H):
0.84 x 0.61 x 0.18 in
SIZE-METRIC (L x W x H):
21.4 x 15.5 x 4.5 mm
MOTOR CURRENT (CONTINUOUS):
2A
MOTOR CURRENT (PEAK):
3A
FUNCTION CURRENT (MAX):
250mA each
NORMAL OUTPUT FUNCTIONS:
10
LOGIC-LEVEL FUNCTIONS:
4*
SERVO OUTPUT FUNCTIONS:
2*
FUNCTION INPUTS:
0
KEEP-ALIVE INTERFACE:
Hardwire - Solder Pad**
KA INPUT VOLTAGE (MAX):
NA
KA TOTAL CAPACITANCE:
NA
CV PROGRAMMING:
Service Mode + P.O.M.
FIRMWARE UPDATE:
Yes - LokProgrammer required
PROTOCOL:
NMRA DCC
BI-DIRECTIONAL COMMUNICATION:
RailCom Plus
ADDITIONAL FEATURES:
NA
NOTES (1):
* - Optional configuration - see manual
NOTES (2):
** - Optional 2 or 3 wire KA interface
View AllClose